Department of Medicine Publications

Document Type

Article

Publication Date

3-1-2024

Journal

NMR in Biomedicine

Volume

37

Issue

3

First Page

5071

Last Page

5071

URL with Digital Object Identifier

https://doi.org/ 10.1002/nbm.5071

Abstract

Single-voxel proton magnetic resonance spectroscopy (SV 1 H-MRS) is an in vivo noninvasive imaging technique used to detect neurotransmitters and metabolites. It enables repeated measurements in living participants to build explanatory neurochemical models of psychiatric symptoms and testing of therapeutic approaches. Given the tight link among glutamate, gamma-amino butyric acid (GABA), glutathione and glutamine within the cellular machinery, MRS investigations of neurocognitive and psychiatric disorders must quantify a network of metabolites simultaneously to capture the pathophysiological states of interest. Metabolite-selective sequences typically provide improved metabolite isolation and spectral modelling simplification for a single metabolite at a time. Non-metabolite-selective sequences provide information on all detectable human brain metabolites, but feature many signal overlaps and require complicated spectral modelling. Although there are short-echo time (TE) MRS sequences that do not use spectral editing and are optimised to target either glutamate, GABA or glutathione, these approaches usually imply a precision tradeoff for the remaining two metabolites. Given the interest in assessing psychiatric and neurocognitive diseases that involve excitation-inhibition imbalances along with oxidative stress, there is a need to survey the literature on the quantification precision of current metabolite-selective MRS techniques. In this review, we locate and describe 17 studies that report on the quality of simultaneously acquired MRS metabolite data in the human brain. We note several factors that influence the data quality for single-shot acquisition of multiple metabolites of interest using metabolite-selective MRS: (1) internal in vivo references; (2) brain regions of interests; (3) field strength of scanner; and/or (4) optimised acquisition parameters. We also highlight the strengths and weaknesses of various SV spectroscopy techniques that were able to quantify in vivo glutamate, GABA and glutathione simultaneously. The insights from this review will assist in the development of new MRS pulse sequences for simultaneous, selective measurements of these metabolites and simplified spectral modelling.

Creative Commons License

Creative Commons Attribution-Noncommercial 4.0 License
This work is licensed under a Creative Commons Attribution-Noncommercial 4.0 License

Find in your library

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.